ATmega8内部RC振荡器漂移测试
发布时间:2008/6/5 0:00:00 访问次数:765
选择atmega8-16pi,内部1m rc,程序为i/o取反操作,agilent infiniium 54833a dso 1ghz 4gsa/s数字示波器测量,lm2825-5供电。
27℃ mean:141.313 min:141.2439 max:141.4173 current:141.0/141.2
35℃ mean:141.245 min:141.0358 max:141.4173 current:140.9/141.0
40℃ mean:141.18 min:140.8892 max:141.4173 current:140.8/140.9
45℃ mean:141.07 min:140.7420 max:141.4173 current:140.7/140.8
50℃ mean:141.03 min:140.6983 max:141.4173 current:140.7/140.8
55℃ mean:141.00 min:140.6458 max:141.4173 current:140.6/140.7
60℃ mean:140.97 min:140.5294 max:141.4173 current:140.5/140.6
65℃ mean:140.94 min:140.4558 max:141.4173 current:140.4/140.5
70℃ mean:140.91 min:140.3302 max:141.4173 current:140.3/140.4
75℃ mean:140.88 min:140.2379 max:141.4173 current:140.2/140.3
80℃ mean:140.84 min:140.0747 max:141.4173 current:140.1/140.2
85℃ mean:140.82 min:139.9755 max:141.4173 current:140.0
90℃ mean:140.76 min:139.8568 max:141.4173 current:139.8
总结:
mean是整个测量范围的平均值,只能作为参考,不能作为评估;min是整个测量范围的最小值,可以作为参考,也可以作为评估(频率漂移和温度成线性关系);max是整个测量范围的最大值,由于随温度升高频率降低,所以该值几乎没有意义;current是当前测量值可以作为参考,也可以作为评估。
从上面的数据可以看出,随着温度的升高,rc振荡器呈现出随温度升高而降低的趋势,但是变化不是很明显,从min的测量值进行频率的漂移计算可以得出:(141.2439-139.9755)/141.2439=0.89%;从current的测量值进行频率的漂移计算可以得出:(141.2-139.8)/141.2=0.85%,基本可以认为从27℃到85℃的温度范围内内部rc震荡器的频率变化了0.8-0.9左右,对于uart而言,这样的变化导致的误码率还是有限的。
频率是个比较难测量的值,以上的mean和current数据都只取了比较稳定的几位,但是大致的频率趋势还是很明显的。
感谢nsc美国国家半导体提供lm2825 dc-dc模块,感谢浙江立德提供免费网站空间,感谢浙江立德提供测试设备!
27℃ mean:141.313 min:141.2439 max:141.4173 current:141.0/141.2
35℃ mean:141.245 min:141.0358 max:141.4173 current:140.9/141.0
40℃ mean:141.18 min:140.8892 max:141.4173 current:140.8/140.9
45℃ mean:141.07 min:140.7420 max:141.4173 current:140.7/140.8
50℃ mean:141.03 min:140.6983 max:141.4173 current:140.7/140.8
55℃ mean:141.00 min:140.6458 max:141.4173 current:140.6/140.7
60℃ mean:140.97 min:140.5294 max:141.4173 current:140.5/140.6
65℃ mean:140.94 min:140.4558 max:141.4173 current:140.4/140.5
70℃ mean:140.91 min:140.3302 max:141.4173 current:140.3/140.4
75℃ mean:140.88 min:140.2379 max:141.4173 current:140.2/140.3
80℃ mean:140.84 min:140.0747 max:141.4173 current:140.1/140.2
85℃ mean:140.82 min:139.9755 max:141.4173 current:140.0
90℃ mean:140.76 min:139.8568 max:141.4173 current:139.8
总结:
mean是整个测量范围的平均值,只能作为参考,不能作为评估;min是整个测量范围的最小值,可以作为参考,也可以作为评估(频率漂移和温度成线性关系);max是整个测量范围的最大值,由于随温度升高频率降低,所以该值几乎没有意义;current是当前测量值可以作为参考,也可以作为评估。
从上面的数据可以看出,随着温度的升高,rc振荡器呈现出随温度升高而降低的趋势,但是变化不是很明显,从min的测量值进行频率的漂移计算可以得出:(141.2439-139.9755)/141.2439=0.89%;从current的测量值进行频率的漂移计算可以得出:(141.2-139.8)/141.2=0.85%,基本可以认为从27℃到85℃的温度范围内内部rc震荡器的频率变化了0.8-0.9左右,对于uart而言,这样的变化导致的误码率还是有限的。
频率是个比较难测量的值,以上的mean和current数据都只取了比较稳定的几位,但是大致的频率趋势还是很明显的。
感谢nsc美国国家半导体提供lm2825 dc-dc模块,感谢浙江立德提供免费网站空间,感谢浙江立德提供测试设备!
选择atmega8-16pi,内部1m rc,程序为i/o取反操作,agilent infiniium 54833a dso 1ghz 4gsa/s数字示波器测量,lm2825-5供电。
27℃ mean:141.313 min:141.2439 max:141.4173 current:141.0/141.2
35℃ mean:141.245 min:141.0358 max:141.4173 current:140.9/141.0
40℃ mean:141.18 min:140.8892 max:141.4173 current:140.8/140.9
45℃ mean:141.07 min:140.7420 max:141.4173 current:140.7/140.8
50℃ mean:141.03 min:140.6983 max:141.4173 current:140.7/140.8
55℃ mean:141.00 min:140.6458 max:141.4173 current:140.6/140.7
60℃ mean:140.97 min:140.5294 max:141.4173 current:140.5/140.6
65℃ mean:140.94 min:140.4558 max:141.4173 current:140.4/140.5
70℃ mean:140.91 min:140.3302 max:141.4173 current:140.3/140.4
75℃ mean:140.88 min:140.2379 max:141.4173 current:140.2/140.3
80℃ mean:140.84 min:140.0747 max:141.4173 current:140.1/140.2
85℃ mean:140.82 min:139.9755 max:141.4173 current:140.0
90℃ mean:140.76 min:139.8568 max:141.4173 current:139.8
总结:
mean是整个测量范围的平均值,只能作为参考,不能作为评估;min是整个测量范围的最小值,可以作为参考,也可以作为评估(频率漂移和温度成线性关系);max是整个测量范围的最大值,由于随温度升高频率降低,所以该值几乎没有意义;current是当前测量值可以作为参考,也可以作为评估。
从上面的数据可以看出,随着温度的升高,rc振荡器呈现出随温度升高而降低的趋势,但是变化不是很明显,从min的测量值进行频率的漂移计算可以得出:(141.2439-139.9755)/141.2439=0.89%;从current的测量值进行频率的漂移计算可以得出:(141.2-139.8)/141.2=0.85%,基本可以认为从27℃到85℃的温度范围内内部rc震荡器的频率变化了0.8-0.9左右,对于uart而言,这样的变化导致的误码率还是有限的。
频率是个比较难测量的值,以上的mean和current数据都只取了比较稳定的几位,但是大致的频率趋势还是很明显的。
感谢nsc美国国家半导体提供lm2825 dc-dc模块,感谢浙江立德提供免费网站空间,感谢浙江立德提供测试设备!
27℃ mean:141.313 min:141.2439 max:141.4173 current:141.0/141.2
35℃ mean:141.245 min:141.0358 max:141.4173 current:140.9/141.0
40℃ mean:141.18 min:140.8892 max:141.4173 current:140.8/140.9
45℃ mean:141.07 min:140.7420 max:141.4173 current:140.7/140.8
50℃ mean:141.03 min:140.6983 max:141.4173 current:140.7/140.8
55℃ mean:141.00 min:140.6458 max:141.4173 current:140.6/140.7
60℃ mean:140.97 min:140.5294 max:141.4173 current:140.5/140.6
65℃ mean:140.94 min:140.4558 max:141.4173 current:140.4/140.5
70℃ mean:140.91 min:140.3302 max:141.4173 current:140.3/140.4
75℃ mean:140.88 min:140.2379 max:141.4173 current:140.2/140.3
80℃ mean:140.84 min:140.0747 max:141.4173 current:140.1/140.2
85℃ mean:140.82 min:139.9755 max:141.4173 current:140.0
90℃ mean:140.76 min:139.8568 max:141.4173 current:139.8
总结:
mean是整个测量范围的平均值,只能作为参考,不能作为评估;min是整个测量范围的最小值,可以作为参考,也可以作为评估(频率漂移和温度成线性关系);max是整个测量范围的最大值,由于随温度升高频率降低,所以该值几乎没有意义;current是当前测量值可以作为参考,也可以作为评估。
从上面的数据可以看出,随着温度的升高,rc振荡器呈现出随温度升高而降低的趋势,但是变化不是很明显,从min的测量值进行频率的漂移计算可以得出:(141.2439-139.9755)/141.2439=0.89%;从current的测量值进行频率的漂移计算可以得出:(141.2-139.8)/141.2=0.85%,基本可以认为从27℃到85℃的温度范围内内部rc震荡器的频率变化了0.8-0.9左右,对于uart而言,这样的变化导致的误码率还是有限的。
频率是个比较难测量的值,以上的mean和current数据都只取了比较稳定的几位,但是大致的频率趋势还是很明显的。
感谢nsc美国国家半导体提供lm2825 dc-dc模块,感谢浙江立德提供免费网站空间,感谢浙江立德提供测试设备!